How to Relight a Furnace Pilot Light Safely
Relight the standing pilot on an older gas furnace: shut the gas, let it clear, then hold the pilot knob and light it. Why it goes out and when to call a pro.
Short answer
Only older gas furnaces have a standing pilot. Turn the gas knob to Off and wait at least five minutes, then turn it to Pilot, hold it down and light the pilot. Keep holding for about a minute, release, and turn the knob to On. If it won't stay lit, the thermocouple is the usual cause.
- Difficulty
- Difficulty: Moderate
- Time
- 10–20 minutes
- Tools
- 4 items
Tools & supplies
- Flashlight
- Long-reach lighter or fireplace matches
- Screwdriver (to remove the access panel)
- Owner's manual or the lighting label on the furnace
In this guide
A pilot light is a small flame that burns all the time and lights the main burners when the thermostat calls for heat. Only older gas furnaces have one. If yours has gone out, relighting it takes a few minutes. Always follow the lighting instructions on the label inside your furnace door, because they take priority over any general guide.
Gas safety: If you smell gas, which smells like rotten eggs or sulfur, don’t light anything or touch electrical switches. Leave the house and call your gas utility or 911 from outside. Never try to relight a pilot while you smell gas.
Check whether your furnace has a pilot
Look through the small window near the bottom of the furnace or remove the burner access panel.
- Standing pilot: a gas valve with a knob marked Off, Pilot and On, and a thin tube leading to a small burner. This guide is for you.
- Electronic ignition: no knob marked Pilot, and a glowing hot surface igniter or a clicking spark igniter. Most furnaces made in the last few decades work this way. There’s nothing to relight. If the burners won’t light, go to furnace not turning on.
Step 1: Turn off the furnace and the gas
- Set the thermostat to Off, or turn it down as low as it goes.
- Turn the furnace’s power switch off. It looks like a light switch on or near the unit.
- Turn the gas control knob to Off.
Step 2: Wait for the gas to clear
Wait at least five minutes, or longer if the label says so. This lets any gas that built up around the burner disperse. If you smell gas after waiting, stop and leave the house.
Step 3: Light the pilot
- Remove the burner access panel and find the pilot burner. It’s usually at the end of a thin tube near the main burners, often next to a thin rod (the thermocouple).
- Turn the gas knob to Pilot.
- Press and hold the knob down, or press the separate red or black pilot button. This lets gas flow to the pilot.
- While holding it, light the pilot with a long lighter. If there’s a red igniter button, press it repeatedly until the pilot lights.
- Keep holding the knob down for 30 to 60 seconds after the pilot lights. This heats the thermocouple, which tells the valve the flame is lit.
- Release the knob slowly. The pilot should stay lit.
Step 4: Turn the furnace back on
- Turn the gas knob to On.
- Replace the access panel.
- Turn the furnace power switch on and set the thermostat to heat.
- The main burners should light within a few minutes.
Check the pilot flame. It should be steady and mostly blue, wrapping around the tip of the thermocouple. A weak, yellow or flickering flame can mean a dirty pilot opening or a venting problem, so have it checked.
If the pilot won’t stay lit
If the pilot lights while you hold the knob but goes out when you let go:
- Hold it longer. Try again and hold for a full minute.
- The thermocouple may be worn or out of position. It must sit in the flame. A thermocouple is an inexpensive part, but because it’s part of the gas safety system, many homeowners have a technician replace it.
- The pilot opening may be dirty. A small, weak flame that doesn’t reach the thermocouple needs cleaning by a technician.
- A draft may be blowing it out. Check for a missing panel, an open window near the furnace or a strong draft from the flue.
The same principles apply to a gas water heater. See water heater pilot light won’t stay lit.
When to call an HVAC technician
- You smell gas at any time.
- The pilot won’t light, or won’t stay lit after two or three tries.
- The pilot flame is yellow, sooty or lifting off the burner.
- The pilot keeps going out every few days.
- A carbon monoxide alarm sounds. Get out and call 911 first. See carbon monoxide detector beeping.
Have a furnace serviced every year before the heating season, especially an older one with a standing pilot.
Common questions
Why does my furnace pilot light keep going out?
The most common cause is a worn thermocouple, which stops sensing the flame and shuts the gas off. A dirty pilot opening, drafts, or a problem with the venting are other causes. If it goes out repeatedly, have a technician check it.
Is it safe to relight a furnace pilot light myself?
Yes, if you follow the lighting label on the furnace exactly, wait for the gas to clear first, and stop if you smell gas. Don’t attempt repairs on the gas valve or gas line.
How long should I hold the pilot button?
Hold it for about 30 to 60 seconds after the pilot lights, so the thermocouple heats up. Releasing too soon is the most common reason a newly lit pilot goes out.
Do all furnaces have a pilot light?
No. Most modern furnaces use electronic ignition and have no standing pilot. If your furnace has no knob marked Pilot, there’s nothing to relight.
Bottom line
Turn the gas off and wait five minutes, then hold the knob on Pilot, light it and keep holding for up to a minute before turning it to On. If it won’t stay lit, the thermocouple is the likely cause and a technician can replace it. Never relight a pilot if you smell gas.